Case 04 / BU ME304 laboratory report draft
Thermal model versus experiment
Compare measured heating and boiling traces with a simplified pot-and-water energy balance, then examine why inferred latent heat differs from the reference.
Team contribution
Team laboratory participation. Individual measurement and analysis roles, the final roster and experiment date remain unresolved; the report is a draft.
Key result
Inferred latent heats are about 49% and 39% below the report reference near 100 °C / 1 atm. Illustrative propagated uncertainty excludes systematic bias and does not resolve the mismatch.
Results and technical detail ↓
View full size Constraints
- Use logger time in minutes and logger starting temperatures.
- Separate measurements, inferred quantities and reference properties.
Analysis and Evidence
The analysis infers average preboiling water-heating power from mass, temperature rise and time: P = m·c·ΔT/Δt, with c = 4,180 J/(kg·K). It reuses that power during boiling and assigns total mass loss to the boiling interval.
That indirect estimate omits changing heat transfer and pot/plate storage. Reusing it in the pot-plus-water Euler model does not provide independently calibrated heater input. The large reference mismatch exposes the limitation rather than validating the model.
The analysis interval ends at 20 min. The complete trace retains Trial 2’s later temperature drop; probe handling is unknown, so the drop is not established as bulk-water cooling.
View full size
View full size Evidence & interpretation
Results & validation
Inferred latent heats are about 49% and 39% below the report reference near 100 °C / 1 atm. Illustrative propagated uncertainty excludes systematic bias and does not resolve the mismatch.
Simplified Euler model includes pot heat storage and approximate convection losses.
reproduced approximate model · teamUses water-only inferred power as pot-plus-water input; not independently calibrated. Radiation, thermal gradients, preboiling evaporation and actual exposed area unresolved.
Trial 1 · initial water mass
0.543 kg
derived from measured massesInitial total mass minus empty pot mass.
Trial 1 · logger start
24.8 °C
measured logger valueLogger start, not manual spreadsheet initial value.
Trial 1 · inferred heating power
284.5 ± 8.9 W
inferred model quantityWater-only average preboiling heating rate; not hot-plate electrical input.
Uncertainty assumptions
Illustrative first-order propagation of assumed independent 1σ inputs; systematic bias excluded; not instrument-certified accuracy or a 95% confidence interval.
- each scale kg
- 0.001
- each temperature C
- 1
- onset min
- 0.25
- endpoint min
- 0.25
Trial 1 · inferred latent heat
1,146 ± 68 kJ/kg
inferred model quantityPreboiling inferred power reused during boiling; total mass loss assigned to that interval. Fails agreement with nominal reference.
Uncertainty assumptions
Illustrative first-order propagation of assumed independent 1σ inputs; systematic bias excluded; not instrument-certified accuracy or a 95% confidence interval.
- each scale kg
- 0.001
- each temperature C
- 1
- onset min
- 0.25
- endpoint min
- 0.25
Trial 2 · initial water mass
0.741 kg
derived from measured massesInitial total mass minus empty pot mass.
Trial 2 · logger start
32.9 °C
measured logger valueLogger start, not manual spreadsheet initial value.
Trial 2 · inferred heating power
330 ± 11 W
inferred model quantityWater-only average preboiling heating rate; not hot-plate electrical input.
Uncertainty assumptions
Illustrative first-order propagation of assumed independent 1σ inputs; systematic bias excluded; not instrument-certified accuracy or a 95% confidence interval.
- each scale kg
- 0.001
- each temperature C
- 1
- onset min
- 0.25
- endpoint min
- 0.25
Trial 2 · inferred latent heat
1,373 ± 84 kJ/kg
inferred model quantityPreboiling inferred power reused during boiling; total mass loss assigned to that interval. Fails agreement with nominal reference.
Uncertainty assumptions
Illustrative first-order propagation of assumed independent 1σ inputs; systematic bias excluded; not instrument-certified accuracy or a 95% confidence interval.
- each scale kg
- 0.001
- each temperature C
- 1
- onset min
- 0.25
- endpoint min
- 0.25
Nominal water reference
2,257 kJ/kg
report reference valueApproximate report reference near 100 °C and 1 atm; not a measured value from this experiment.
Engineering limitations
Water-only inferred power is reused for boiling and for a pot-plus-water model. Uncertainty uses assumed tolerances and excludes systematic bias. Actual electrical input, calibration, roster and experiment date are unconfirmed.